Bluebell BC160P - 19" 1RU Chassis for up to 6 Passive BCxxx Cards

83632

New

19" 1RU Chassis for up to 6 Passive BCxxx Cards. No psu or monitoring capability

Visuals price :

496,80 CHF


537,04 CHF (tax incl.)  

Rectangle
Guarantee: garantie Visuals Guarantee 60 Months
In-house aftersales service: update, repair and backup.

Availability: clock

Usually ships within 2 to 3 weeks


Order now and we will deliver as soon as possible,
or please contact us on 022 561 07 07 for other arrangements.

- +

83632
More info  

The BC160 is a 19” 1RU chassis for Bluebell BC Series cards. Any of the standard cards can be fitted and mixed within each frame. The BC160 can hold up to 6 single slot cards. Redundant power supplies are supplied as standard. 
Some BC Series processing cards have dual functionality allowing up to 12 channels of video to be transmitted or received from a single 1RU frame, while retaining loop through inputs and dual outputs per channel.

Signal and card monitoring is achieved through SNMP monitoring in the BM101 network card.

Alternatively GP-Output alarms can be triggered via the BM100 module.

The BC160P is the same physical footprint but without any signal monitoring or power supplies, it is specifically intended to house passive optical modules including splitters, WDM and CWDM devices.


Key Features


- Compact Design
- High Packing Density
- Low Power Consumption
- Dual Power Supplies
- Alarms via GPI or SNMP 


Use BC160P with active frames for ultra compact optical multiplexing and distribution


General frame specifications


- Depth 150 mm (excluding connectors)

- Width 445 mm

- Height 44.5 mm (1RU)

- Weight 4.5 kg when fully loaded

- Operating Temp -30 to +70 0

- Voltage Range 90 to 260 V ac 50/60 Hz

- Power 18 W when fully loaded

- Signal detect Contact closure for psu failure

- No of slots 6


Conformance


- EMI/RFI Complies with 89/336/EEC

- Electrical Complies with EN 61000-6-1, EN61000-6-2

- RoHS Complies with Directive 2002/95/EC 


The BM100 network card allows for external alarms to be triggered via GPO relays on a SCSI connector.
The card is fitted to the front of the BC160 frame.
Any signal or power supply failure within the frame triggers an alarm.



The BM101 network card monitors the status of signals and power supplies within the frame.
The Ethernet port allows a third party SNMP management system to receive signal and power supply failure alarms.
The card is fitted to the front of the BC160 frame.